TOC / Total Organic Carbon Analyzer, TOC-M2000

  1. Detector: NDIR
  2. Parameters: TC, TIC, TOC, NPOC
  3. Measurement Range: 0-50000 mg/l (ppm)
  4. Detection Limit: 50μg/l (ppb)
  5. Gas Requirement: Oxygen ≥ 99.995%
  6. Digestion Mode: High Temperature Combustion

Share the product

Category:

Description

Total Organic Carbon Analyzer / TOC Analyzer

  1. High-performance processor,ensuring stable and reliable system running.
  2. Modular design,simplifying device operation and maintenance.
  3. Imported NDIR detector,guaranteeing higher sensitivity and stability.
  4. PID temperature controlling technology,reaching higher accuracy.
  5. Precise gas flow control technology improves accuracy.
  6. Unique three-stage dehydration technology improves drying efficiency.
  7. Optional 20-position autosampler saves 80% time and energy.
  8. Unique liquid path and flow control system extend the service life of catalyst.
  9. Real-time monitoring of diluted water and waste water.
  10. Multi-functional PC software,complying with the requirements of GMP.
  11. Personalized standard curve management provides great convenience for users.
  12. Consumables management reminds users to replace consumables in time.
  13. 680℃ catalytic oxidation technology with Platinum catalyst, especially for seawater test.

Core Parts

High Temperature Pyrolysis Module

  • Pyrolysis temperature can be set as required.
  • Precision temperature control system, the highest temperature 1000℃

IC Reaction Module

  • Complete IC digestion by acid-adding and heating.
  • Electronic cooling system, filter and membrane dryer effectively remove the water vapor.

NDIR Detector

  • Imported light source, detector and special gas chamber.
  • Stable results, lower noise, wider detection range and faster speed.
  • A constant temperature environment ensures high stability and accuracy.

Specifications

 Model TOC-M2000
 Detector NDIR
 Parameters TC, TIC, TOC, NPOC
 Digestion Mode High Temperature Combustion
 Operation Mode PC software Control
 Application Liquid Sample
 Gas Requirement Oxygen ≥ 99.995%
 Measurement Range 0-50000mg/L (manually dilution)
 Detection Limit 50μg/l (ppb)
 Repeatability 3%
 Power AC220V, 50Hz or AC110V, 60HZ, 200W
 Size 450*500*480mm